13
ACA Current (Clamp-on)
RANGE Accuracy
1) 2)
400.0A
15Hz ~ 40Hz 2.0% + 5d
3)
40Hz ~ 200Hz 1.5% + 5d
200Hz ~ 400Hz @ <50A
4)
1.5% + 5d
400Hz ~ 1kHz @ <50A
4)
2.0% + 5d
800A
15Hz ~ 40Hz @ 400A ~ 600A 2.0% + 5d
3)
40Hz ~ 100Hz @ 400A ~ 600A 1.5% + 4d
15Hz ~ 60Hz @ 600A ~ 800A 5.0% + 30d
1)
Induced error from adjacent current-carrying conductor: < 0.01A/A
2)
ACDC-100 TRMS crest Factor: < 1.6 : 1 at full scale & < 3.2 : 1 at half scale
3)
4.0% + 5d for ACDC-100 TRMS
4)
Accuracy is specified at <50A in this frequency bandwidth due to limited calibrator