USER'S
MANUAL
ACDC-100 TRMS
ACDC-100
Versatile AC/DC
Clamp-on Multimeter
Series
99 Washington Street
Melrose, MA 02176
Fax 781-665-0780
TestEquipmentDepot.com
Vue de la page 0
1 2 3 4 5 6 ... 13 14

Résumé du contenu

Page 1 - USER'S

USER'S MANUAL ACDC-100 TRMS ACDC-100 Versatile AC/DC Clamp-on Multimeter Series 99 Washington Street Melrose, MA 02176

Page 2

9Battery replacement The meter uses standard 1.5V AAA Size (NEDA 24G or IEC R03) battery X 2; or 1.5V AAA Size (NEDA 24A or IEC LR03) alkaline batter

Page 3

106) SPECIFICATIONS General Specifications Display : 3-3/4 digits 4000 counts LCD display(s) Update Rate : 3 per second nominal Polarity : Automatic

Page 4

11Electrical Specifications Accuracy is ±(% reading digits + number of digits) or otherwise specified, at 23oC ± 5oC & less than 75% R.H. ACDC

Page 5

12Ohms RANGE Accuracy 400.0Ω 0.8% + 6d 4.000kΩ, 40.00kΩ, 400.0kΩ 0.6% + 4d 4.000MΩ 1.0% + 4d 40.00MΩ 2.0% + 4d Open Circuit Voltage : 0.4VDC typical

Page 6

13ACA Current (Clamp-on) RANGE Accuracy1) 2) 400.0A 15Hz ~ 40Hz 2.0% + 5d 3) 40Hz ~ 200Hz 1.5% + 5d 200Hz ~ 400Hz @ <50A 4) 1.5% + 5d 400Hz ~ 1

Page 7

11) SAFETY This manual contains information and warnings that must be followed for operating the instrument safely and maintaining the instrument in

Page 8

2WARNING To reduce the risk of fire or electric shock, do not expose this product to rain or moisture. The meter is intended only for indoor use. T

Page 9

33) PRODUCT DESCRIPTION This user's manual uses only representative model(s) for illustrations. Please refer specification details for function

Page 10

44) OPERATION DC Voltage and AC Voltage functions Inputs are made through the test lead terminals. Note: DC 400.0mV range is designed with 1000MΩ

Page 11

5 ACA & DCA Current clamp-on function Inputs are made through the clamp jaws for non-invasive ACA & DCA current measurements. CAUTION (App

Page 12

6 CAUTION Using Resistance, Continuity or Diode function in a live circuit will produce false results and may damage the instrument. In many cases t

Page 13

7 Capacitance function Inputs are made through the test leads terminals. Slide-switch on defaults at Ω. Press SELECT button momentarily 3 times to se

Page 14

8Display Backlight (ACDC-100 TRMS only) Press the SELECT button for 1 second or more to toggle the display backlight on and off. Auto Power Off (APO