User Manual
• Bedienungshandbuch
• Mode d’emploi
• Manuale d’Uso
• Manual de uso
• Bruksanvisning
ACD-14 FX
ACD-14 TRMS FX
Vue de la page 0
1 2 3 4 5 6 ... 18 19

Résumé du contenu

Page 1 - ACD-14 TRMS FX

User Manual• Bedienungshandbuch• Mode d’emploi• Manuale d’Uso• Manual de uso• BruksanvisningACD-14 FXACD-14 TRMS FX

Page 2

8 Diode test function Inputs are made through the test lead terminals. Move the slide-switch to the “Ω” position. The unit defaults at Ω. Press SELEC

Page 3 - Owner’s Manual

9ACA Current clamp-on functionInputs are made through the clamp on jaws for non-invasive ACA current measurements.Press the OFF push button momentaril

Page 4

10Make sure the jaws are completely closed, or else it will introduce measurement errors.Strong Electro-magnetic field environments such as high-curren

Page 5 - Safety Regulations

11Application notes:The DC µA function is designed especially for HVAC/R flame sensor applications. The 0.1µA resolution is useful for identifying the

Page 6

12Auto-rangingWhen there is more than one measuring range under a selected meter function, the LED annunciator “a” turns on in the upper left corner.

Page 7 - Product Description

13Battery replacementThe meter uses 2 standard 3V alkaline button batteries (ANSI/NEDA-5004LC, IEC-CR2030). The lower battery is used for the slide-sw

Page 8 - Operation

14SpecificationsGeneral SpecificationsDisplay: 3-3/4 digits 4000 counts, dual LCD displaysUpdate Rate: 3 per second nominalPolarity: AutomaticLow Batter

Page 9

15Standard Accessories:Test leads (pair), banana plug style, bead Type-K Thermocouple, batteries, user’s manual, & soft carrying case.Replacement

Page 10

16OhmsRANGE Accuracy400.0Ω 0.8% + 6d4.000kΩ, 40.00kΩ, 400.0kΩ0.6% + 4d4.000MΩ 1.0% + 4d40.00MΩ 2.0% + 4dOpen Circuit Voltage: 0.4VDC typicalAudible Co

Page 12

ACD-14 FX ACD-14 TRMS FXOwner’s Manual

Page 13

1Limited Warranty and Limitation of LiabilityYour Amprobe product will be free from defects in material and workmanship for 1 year from the date of pu

Page 14 - Maintenance

2ACD-14 FXACD-14 TRMS FXContents:Safety Regulations ...

Page 15

3Congratulations! Your new instrument has been crafted according to quality standards and contains quality components and workmanship. It has been ins

Page 16 - Specifications

4 WARNING:To reduce the risk of fire or electric shock, do not expose this product to rain or moisture. The meter is intended only for indoor use.To a

Page 17

5Product DescriptionNote: Please refer to Specification Section for function details.1) Clamp Jaw for AC current magnetic field pick up2) Hand/Finge

Page 18

6OperationDC Voltage, AC Voltage, Hz Frequency functionsInputs are made through the test lead terminals. Move the slide-switch to the “V” position. Th

Page 19

7Note: Hz input sensitivity varies automatically with function range selected while activating the Hz function. Lowest range has the highest sensitivi